Designing Air Coolers Equipped With Heat Exchangers

Document Type : Research Paper

Abstract

In this study, a method for evaluation of pressure drop of air cooler heat exchangers was developed which is based on the maximum pressure drop value. Due to the procedure used in full pressure drop absorption, the heat exchanger designed in this study are smaller than most common procedures which leads to lower capital investment of heat exchangers. It was concluded that the proposed procedure can be successfully used in high efficiency enhanced heat exchangers, where tube inserts are employed as the enhancement element

Keywords


[
1] Jegede F.O. & Polley G.T., “Optimum heat exchanger design”, Trans. IChemE, Vol. 70, Part A, pp. 133-141, 1992.
[2] Polley G.T., “Application of heat transfer enhancement”, www.pinchtechnolgy. com.
[3] Andrew Bailey, Ian Cibbard; “Improving heat exchanger reliability with heat transfer enhancement”, Cal Gavin Limited, Process Identification on Engineering Station Road, Alcester Warwickshire. B49 5ET,UK.
[4] Polley G.T., Nasr J. & Terranova A., “Determination and application of the benefits of heat transfer enhancement”, Trans IChemE, Vol. 72, Part A, 1994.
[5] McMullan A.S., Vertiech.USA, “Case studies of refinery fouling reduction”, Engineering Foundation on “Fouling Mitigation of Industrial Heat Exchanger” 18-23 June 1995, California, USA.
[6] Jafari Nasr M.R and Alaei S.H. , “A new algorithm for design, simulathion and optimization of enhanced air coolers”, Journal of Enhanced Heat Transfer, USA, Vol. 14, pp. 147-160, 2007.